When planning the lighting of workplaces, the standards DIN EN 12464-1 for indoor workplaces, DIN EN 12464-2 for outdoor workplaces and DIN EN 1838 for emergency lighting as well as the technical rules for workplaces ASR 3.4 lighting and ASR 3.4/3 safety lighting come into use. You can find more information on this in our blog post
WORKPLACE LIGHTING – STANDARDS AND REGULATIONS
They contain specifications about the average and minimum illuminance to be maintained, as well as the resulting uniformity of the lighting. GOSSEN has developed a special grid measurement function (GRID) for this purpose and implemented it in the MAVOMASTER, the universal basic device of the new light measurement system. When the measuring function is activated, the current measured value of the grid point is accepted at the push of a button, Emin / Emax / Eavg / U0 / UD of the measurement series is automatically calculated and made available for retrieval. This means that the workplace lighting can already be assessed during the measurement. When the measurement function is ended, all measured values and the values calculated from them can be saved in CSV format and are available for creating an acceptance report.
MAVOMASTER Screenshots – grid measurement function (GRID)
The MAVOLUX 5032 B kit contains the MAVOMASTER and the MAVOPROBE 5032 B with very high resolution and accuracy. This means that the user is ideally equipped to check the illuminance in accordance with the standards and rules listed above.